Duradek is an outdoor vinyl flooring system that provides an attractive, finished walking surface and roofgrade waterproofing in a single-ply, single product solution.
Since 1974 over 150 million square feet of Duradek outdoor vinyl flooring has been successfully waterproofing sun decks, balconies, roof decks and more.
The Duradek system is easily integrated into the building envelope to assist in managing water away from the structure, thus protecting the building and extending its life.
DURADEK™ ULTRA PVC SHEET MEMBRANE
Duradek™ Ultra Product Features
- 60 mil thickness
- 15 year waterproofing warranty
- 5 year appearance warranty
- Textured for slip resistance – meets ADA requirements
- UV and mould inhibitors for extended life
- Useable immediately after installation (no curing time)
- Only maintenance is occasional cleaning (no re-coating needed)
- ICC listed as a Thermoplastic Roofing Membrane (AC 75) and a Pedestrian Traffic Coating (AC 39)
- Class A & C Fire rated assemblies
- Expands and contracts with substrate without cracking (tested to -40 + 1oC)
- Installed only by authorized and trained contractors using sound roofing details
- Specially formulated adhesives and color coordinated trim pieces
- Over 20 color/pattern options available
PHYSICAL PROPERTIES
- Calendared polyvinyl chloride (PVC) film laminated to a woven, heat-set polyester fabric.
- Surface is factory printed and top-coated with a PVC/acrylic finish.
- Weight: 55 oz. per sq. yd. (1864 g/m2) .
- Thickness: nominally 0.060 inch [60 mils (1.5 mm)].
- Width: 72 inch (182.88 cm).
- Length: master rolls 25 yards (22.86 m) /or cut to order.
Tests And Evaluation
Code Compliance | ICC-ES No. 2151 | Thermal and Moisture Protection Evaluation Report Compliance with 2012 and 2015 IBC & IRC - Section 07 18 13 Pedestrian Traffic Coatings - Section 07 54 00 Thermoplastic Roofing Membrane - Section 07 54 19 Polyvinyl Chloride Roofing |
FBC Report No. FL20069.2 | Compliance with 2017 Florida Building Code | |
TDI Report No. RC-477 | Meets Texas Department of Insurance Requirements | |
CGSB QAI Report No. RJ0449P-1R1 | Compliance with CAN/CGSB 37.54-95 - Polyvinyl Chloride Roofing & Waterproofing Membrane Type 3, Class B | |
CCMC Report No. 13134-R | Compliance with 2010 NBC - Traffic Coating and Walkable Roofing Membrane over Habitable or Rated Space | |
Independent Quality Control | QAI Listing No. B1023-2 | Quality Auditing Institute - an accredited third party product certification body to ensure consistent product quality |
Fire Classification | QAI Engineering Evaluation RJ0720F-1 & RJ5052F-1 | ASTM E108-08 Fire test of roof covering methods. - Class A and Class C fire rated assemblies |
QAI Engineering Evaluation T731-2 & T731-8 | CAN/ULC S107-3 Methods of fire tests of roof coverings. - Class A and Class C fire rated assemblies | |
Wind Uplift | QAI Test Report No. RJ0913P-1R2 | Passed ANSI/FM 4474 (2004) - to evaluate the wind uplift resistance of roof assemblies |
Edge Flashing Pulloff Resistance | Farabaugh Test Report No. T128-11 | Passed ANSI/SPRI ES-1 wind design standard - for edge systems used with low slope roof systems |